56 Physical Controls
MX3X Reference Guide E-EQ-MX3XRG-H
USB Client Cable
Port Label on Endcap
Mobile Device End Goes To USB Type B Plug End
1 Not Used
2 Not Used
3 D + (Green Wire) 3
4 Not Used
5 Ground (Black Wire) 4
6 Not Used
7 D – (White Wire) 2
8 Not Used
9 Power 1
Figure 2-12 USB Type B to Serial Port Cable Pinout
Connect from USB-H serial port to USB Type B Male receptacle on a USB hub, camera, etc.
Tethered Scanners
Do not connect a tethered scanner cable to a mobile device’s USB-C or USB-H labeled endcap
port. These ports cannot power a tethered scanner. Tethered scanners connect to RS232-labeled
ports on the endcap and can connect to the RS232 port on a powered cradle.
The Scan buttons have no effect on tethered barcode scanners (connected to a serial port).
Tethered scanners read barcode scans only when the trigger on the tethered scanner is pressed. The
tethered scanner requires power on pin 9 of the mobile device’s serial port.
To set the MX3X to use a tethered scanner, select Start | Settings | Control Panel | Scanner |
COM1 (or 2 or 3).
Tap the “Power on Pin 9 (+5V)” checkbox for the COM port selected. The COM port that accepts
the scanner data can be configured for data rate, parity, stop bits and data bits.