54 Physical Controls
MX3X Reference Guide E-EQ-MX3XRG-H
LXE Connection Cable Technical Specification
The exact serial cable is crucial. Many commercial null modem cables will not work. LXE
recommends the following cable:
Serial cable:
9000A054CBL6D9D9
Pinout:
D9 female D9 female
1 7
2 3
3 2
4 6, 8
5 5
6, 8 4
7 1
9 no connection
Figure 2-9 Pinout – Serial Cable for Synchronization
Some laptop devices do not properly implement all control lines on the serial port – the laptop
connection will not work.
RTS/CTS Handshaking and the Serial Port
RTS Ready to Send CTS Clear to Send
DTR Data Terminal Ready DSR Data Set Ready
Remote Side
The device sending data to and receiving data from the MX3X
through the LXE serial cable connected to the RS-232 ports on
both devices.
LXE Serial Cable 9000A054CBLD9D9
The MX3X serial port supports four types of handshaking via the LXE serial cable: None,
standard Xon/Xoff, standard DTR/DSR, and a form of RTS/CTS.
To use RTS/CTS, the remote side computer must clear the DTR line which sets the MX3X CTS
line and allows the MX3X to send data to the remote side.
And then signals and data travel smoothly between both devices.